loading

One-Stop Services For Various Load Bank/EV Charger Pile Tester/Auto Testing Equipment/AC or DC Source Solution

Uninterruptible Power Supply Test System for Reliable Energy Solutions 1
Uninterruptible Power Supply Test System for Reliable Energy Solutions 1

Uninterruptible Power Supply Test System for Reliable Energy Solutions

UPS power supply plays an important role in the power supply system . In order to ensure the safety of the power system and the continuity of power supply, and to avoid major safety hazards in the normal power supply of UPS.

According to the UPS test methods and steps, a complete set of test equipment and test software are integrated specifically for UPS performance testing. Through the local touch screen industrial computer or remote use of wifi/network cable connection, through the dedicated host computer test software configured by VILVA, various tests on the UPS can be realized. This functional test has greatly improved the R&D/production efficiency of UPS, and at the same time guaranteed the factory performance of high-power UPS power supply.
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product advantages

    Meet single-phase/three-phase UPS test;
    Contains DC input, main input, bypass input, UPS output and charging load interfaces;
    The DC input includes DC Source input and battery input (optional), which are interlocked and related; the DC input interface has an N line;
    The main input includes mains input and AC Source input, and the two are interlocked and related;
    The bypass input includes mains input and AC Source input, and the two are interlocked and related;
    The UPS output is configured with full power R load/RL load/RCD load (optional);
    Each input and output interface has voltage, current and other electrical parameter sampling and instrument display;
    External RS485 interface, network port and USB interface are reserved to facilitate communication with customers' external instruments;
    The input and output interfaces use high-current industrial quick-plug connectors to facilitate prototype wiring;
    All instruments and meters are equipped with remote control functions and are uniformly controlled by the host computer;
    Configure charging load, pure resistive load and non-linear load for UPS testing;
    Phase-to-phase short circuit and phase-to-zero short circuit test;
    Emergency stop protection, load over-temperature alarm and protection.
    b1 (34)
    6-
    7 (5)

    product details

    c4 (5)
    c4 (5)
    c3 (5)
    c3 (5)
    c2 (5)
    c2 (5)
    c1 (5)
    c1 (5)

    Product parameters

    Product model Rated voltage Voltage range AC SOURCE Configuration DC SOURCE Configuration Battery cabinet configuration DC load configuration Box size  W*D*H (mm)
    VILVA-VATE UPS test system
    VILVA-VATE60KW-UPS 60 0-60 VILVA-MOD60 VILVA-MDC60 VILVA-DC380V/480V-60KW VILVA-DC1000V-10KW-R 2400*1000*2200mm
    VILVA-VATE100KW-UPS 100 0-100 VILVA-MOD100 VILVA-MDC100 VILVA-DC380V/480V-100KW VILVA-DC1000V-20KW-R 2600*1000*2200mm
    VILVA-VATE200KW-UPS 200 0-200 VILVA-MOD200 VILVA-MDC200 VILVA-DC380V/480V-200KW VILVA-DC1000V-20KW-R 3200*1000*2200mm
    VILVA-VATE300KW-UPS 300 0-300 VILVA-MOD300 VILVA-MDC300 VILVA-DC380V/480V-300KW VILVA-DC1000V-40KW-R 3200*1000*2200mm
    VILVA-VATE500KW-UPS 500 0-500 VILVA-MOD500 VILVA-MDC500 VILVA-DC380V/480V-500KW VILVA-DC1000V-40KW-R 4000*1000*2200mm
    VILVA-VATE600KW-UPS 600 0-600 VILVA-MOD600 VILVA-MDC600 VILVA-DC380V/480V-600KW VILVA-DC1000V-100KW-R 4500*1000*2200mm
    VILVA-VATE900KW-UPS 900 0-900 VILVA-MOD900 VILVA-MDC900 VILVA-DC380V/480V-900KW VILVA-DC1000V-100KW-R 5000*1000*2200mm
    VILVA-VATE1200KW-UPS 1200 0-1200 VILVA-MOD1200 VILVA-MDC1200 VILVA-DC380V/480V-1200KW VILVA-DC1000V-100KW-R 6500*1000*2200mm
    VILVA-VATE2500KW-UPS 2500 0-2500 VILVA-MOD2500 VILVA-MDC2500 VILVA-DC380V/480V-1200KW VILVA-DC1000V-200KW-R 8000*1000*2200mm
    Product model AC load configuration
      VILVA-VATE UPS test system
    VILVA-VATE60KW-UPS 1、VILVA-AC380V-63KW-R    2、VILVA-AC380V-63KW-RLC    3、VILVA-AC380V-63KW-RCD
    VILVA-VATE100KW-UPS 1、VILVA-AC380V-108KW-R    2、VILVA-AC380V-108KW-RLC    3、VILVA-AC380V-108KW-RCD
    VILVA-VATE200KW-UPS 1、VILVA-AC380V-213KW-R    2、VILVA-AC380V-213KW-RLC    3、VILVA-AC380V-213KW-RCD
    VILVA-VATE300KW-UPS 1、VILVA-AC380V-303KW-R    2、VILVA-AC380V-303KW-RLC   3、VILVA-AC380V-303KW-RCD
    VILVA-VATE500KW-UPS 1、VILVA-AC380V-510KW-R   2、VILVA-AC380V-510KW-RLC    3、VILVA-AC380V-510KW-RCD
    VILVA-VATE600KW-UPS 1、VILVA-AC380V-606KW-R   2、VILVA-AC380V-606KW-RLC    3、VILVA-AC380V-606KW-RCD
    VILVA-VATE900KW-UPS 1、VILVA-AC380V-909KW-R   2、VILVA-AC380V-909KW-RLC   3、VILVA-AC380V-909KW-RCD
    VILVA-VATE1200KW-UPS 1、VILVA-AC380V-1212KW-R   2、VILVA-AC380V-1212KW-RLC   3、VILVA-AC380V-1212KW-RCD
    VILVA-VATE2500KW-UPS 1、VILVA-AC380V-2505KW-R   2、VILVA-AC380V-2505KW-RLC   3、VILVA-AC380V-2505KW-RCD
    Communication interface: Ethernet/RS485
    Special specifications can be customized according to customer requirements (voltage, power, size, customized model cycle is slightly longer)
    Contact Us
    To find the best products, just work with us.
    Take a look around our website. If you have a query or you need advice, just contact us. We'll take time to help you. If you require the top-quality products, feel free to contact us.
    sales@vilva-test.com
    +86 18128682585
    Related Products
    We focus on providing load bank,EV Charger Pile Tester,PV Invert Test,UPS Aging Test,PCBA test solution,Data collection and analysis solution,AC/DC source & load solution,Aging system test for various industries
    Contact Us
    Add: 2nd Floor, Building A2, Songhu Zhigu Industrial Park, Liaobu Town, Dongguan City, Guangdong, China
    Contact person: lisa
    Tel: +86 18128682585
    Customer service
    detect