Product Description
VILVA-Fan Cooled Load Bank
Single-phase AC 220V (for IT branch circuits, C13/C14 sockets testing)
| Basic Type | Rated Power | Overall Height | Power Adjust Method | Rated Current | Machine Size (W×H×D) | Net Weight |
| VILVA-AC220V-3KW-RF | 3kW | 4U | Power Steps 0.5/1/1.5KW | 13.6A | 482×178×500mm | 22kg |
| VILVA-AC220V-6kW-RF | 6kW | 6U | Multi-stage power superposition | 27.3A | 482×178×500mm | 28kg |
| VILVA-AC220V-10kW-RF | 10kW | 6U | Stepless adjustment range 0-10 kW | 45.5A | 482×266×520mm | 37kg |
| VILVA-AC220V-12kW-RF | 12kW | 6U | 7 independent switchable power stages | 54.5A | 482×266×520mm | 41kg |
Three-phase AC 380/400/415V(for testing three-phase PDU incoming power and overall rack main power supply
Suitable for supporting use with air-cooled auxiliary heat sources of GB200/GB300 cabinets.
| Basic Type | Total Rated Power | Overall Weight | Power Supply | Single-phase Rated Current | Adjustment Accuracy |
| VILVA-AC380V-15KW-RF | 15KW | 6U | 3P4 Line AC380V | 22.8A | 0.1KW step-less continuous adjustment |
| VILVA-AC380V-24KW-RF | 24kW | 8U | 3P5 Line AC400V | 36.5A | Independent switching per branch |
| VILVA-AC380V-30kW-RF | 30kW | 8U | 3P5 Line AC415V | 43.3A | Remote programmable 0-100% |
VILVA-Liquid Cooled Load Bank
Single-phase AC 220V (for branch circuit testing of single-node servers)
| Type | Rated Power | Overall Weight | Adjustment Method | Rated Current | Machine Size(W×H×D) |
| VILVA-AC220V-10KW-LB | 10kW | 4U | 0-10kW Stepless Adjustable | 45.5A | 482×178×520mm |
| VILVA-AC220V-15KW-LB | 15KW | 6U | Multi-stage Switching | 68.2A | 482×266×520mm |
Three-phase AC 380/400/415V (GB200/GB300)
| Total Types | Total Rated Power | Rack U Height | Power Supply | Single-phase Rated Current | Power Step |
| VILVA-AC400V-20KW-LB | 20kW | 4U | 3P5 Line AC400V | 28.9A | 0.1KW |
| VILVA-AC415V-40KW-LB | 40kW | 6U | 3P5 Line AC415V | 57.8A | 0.1kW |
| VILVA-AC415V-60KW-LB | 60kW | 8U | 3P5 Line AC415V | 86.7A | 1WHigh Precision Power Step |
| VILVA-AC415V-96KW-LB | 96KW | 12U | 3P5 Line AC415V | 138.7A | Independent adjustment for each channel |
Hybrid Air-Liquid Cooling Simulated Load Bank
GB200 TYPE
| Type | Total Rated Power | Air-cooled zone power | Liquid-cooled zone power | Input voltage standard | Applicable objects |
| VILVA-AC415V-208KW-J | 208kW | 24KW | 184KW | AC415V/3P5 | GB200 NVL72 Complete Rack |
| VILVA-AC400V-215KW-J | 216kW | 24KW | 192KW | AC400V/3P5 Line | GB200 High-Density Expansion Rack |
| VILVA-AC380V-120KW-STD | 120KW | 15KW | 105KW | AC380V | Single /Half Rack GB200 Node Test |
ELECTRICAL PARAMETERS
● Rated Voltage: AC380V/400V/415V+10%, Three Phase Five Lines.
● Frequency: 50Hz/60Hz Adaption.
● Power Factor: ≥0.98,THDI (Total Harmonic Distortion of Input Current) < 5%.
● Wiring Mode: Industrial 63A CEE Dual redundant connection with quick connectors and aviation plugs, equipped with 3-meter power cables.
● Adjustmen Power: 0-100% Stepless continuous adjustment with 1kW power step, remote programmable control.
● Standard Rack: 48U industrial server cabinet, 600 (W) × 1066 (D) × 2200 (H) mm.
● Mobile structure: Heavy-duty universal casters with locking brakes at the bottom.
● Designed inlet liquid temperature: 20~25°C (maximum withstand temperature: 45°C.
● Total rated flow per cabinet: 80 L/min.
● Allowable flow resistance: <1.2 bar.
● Integrated PDU: The cabinet is equipped with 8 independent branch circuit breakers inside, supporting independent switching of power per branch.
● Protection Grade: IP20 (Indoor installation in computer room.
● Triple interlock protection: Millisecond-level load cut-off triggered by low flow, overpressure and liquid leakage detection.
● Multi-point PT100 temperature measurement for the whole unit, automatic power derating upon overheating protection.
● Communication Interfaces: Local touch screen + 1000M Ethernet group control, supporting Modbus TCP and SNMP protocols.
● Data Storage: Real-time recording of power, temperature, flow and pressure curves, automatic data export, and generation of Excel-format acceptance reports.
● Noise Level: Less than 70dB at full load, much quieter than traditional air-cooled load banks.
● Design temperature difference between inlet and outlet liquid: 8–12°C.
● Interface Specification: Standard quick-disconnect liquid cooling connectors, compatible with original NVIDIA CDU pipeline interfaces.
● Monitoring items: inlet/outlet liquid temperature, instantaneous flow rate, pipeline pressure, liquid leakage detection, cold plate wall temperature, multi-point data acquisition.
AIR-COOLING ZONE PARAMETERS
● Redundant configuration of forced axial flow fans with variable frequency speed regulation.
● Adjustable outlet air volume to simulate internal air duct resistance of servers.
● Independent temperature collection to verify the threshold of computer room return air temperature.
GB300 TYPE
The power consumption and heat flux density of GB300 NVL72 single cabinet are significantly increased compared with GB200. The peak power consumption of a single cabinet can reach the 250kW level. The power rating of the load is upgraded synchronously, and the partition ratio of air cooling and liquid cooling is optimized simultaneously
| Type | Total Rated Power | Fan Cooled Power | Liquid Cooled Power | Power Supply | Applicable Models |
| VILVA-AC415V-250kW-G3 | 250KW | 30kW | 220kW | AC415V3P5 Line | GB300 NVL72 Standard Complete Rack |
| VILVA-AC480V-300KW-L2A | 300KW | 35KW | 265KW | AC480V customization | GB300 Ultra High Density Expansion Rack |
| VILVA-AC400V-130KW-HALF | 130kW | 16KW | 114KW | AC400V | GB300 Half Rack Node Test |
ELECTRICAL PARAMETERS
● Coolant: Deionized pure water / Special OAT antifreeze with controllable conductivity.
● Design flow rate per cabinet: >95 L/min.
● Cold plate pressure resistance: Max. 1.6 bar.
● Heat density zoning: Adjustable flow for independent branches of GPU cold plates, replicating distributed heat generation of 72 B300 GPUs.
● Temperature Rise Control: The temperature rise of the full-load complete rack is less than 15°C, fully complying with the thermal design limits of GB300 complete racks.
● Supports daisy-chain Ethernet cluster synchronous control for up to 80 load cabinets, enabling batch linkage testing of the entire computer room.
● Modular power units; failure of a single branch will not affect the load operation of other circuits of the whole unit.
● Supports parallel expansion; multiple load banks can be paralleled to simulate the total load of multi-cabinet computing clusters
TECHNICAL ADVANTAGES
● High-fidelity operating condition replication: Independent power regulation for air-cooled and liquid-cooled zones, capable of simultaneously verifying two heat dissipation systems including liquid cooling CDU and computer room air conditioning.
● Greatly reduced test costs: No need to deploy million-level genuine GB200/GB300 computing servers for full-load aging tests. The dummy load can operate continuously 7×24h repeatedly over long term without any chip wear and tear.
● Full-dimensional quantitative acceptance: Automatically collect complete data including electric power, three-phase current and voltage, inlet/outlet liquid temperature, flow rate, pressure difference, cabinet supply and return air temperature, and directly generate acceptance documents for computer room infrastructure.
● Easy installation and deployment: Standard 48U integrated cabinet delivered as a whole unit. Testing can be initiated right after power-up and liquid cooling pipeline connection, with no on-site assembly or commissioning needed.
● Wide compatibility & customizable design: Voltages (380V/400V/415V/480V), power stages, liquid cooling connector types and communication protocols can all be customized as required, compatible with mainstream domestic and foreign CDU and liquid cooling pipeline brands.
DELIVERY LIST
● Factory inspection report and type test certificate for complete equipment.
● Original full PDF datasheets (electrical, liquid cooling, mechanical and communication protocol manuals.
● Touch screen operation manual and remote group control host PC software.
● Supporting power cables, liquid cooling quick disconnect fittings and installation fixing accessories.
● Test data export templates and acceptance report generation tool.
● One-year warranty and on-site commissioning service specification.
SELECTION SUGGESTIONS
● For standard GB200 NVL72 racks: Preferred model VILVA-AC415V-208kW-J.
● For infrastructure acceptance of standard GB300 complete racks: Recommended model VILVA-AC415V-250kW-G3.
● Overseas computer rooms with 480V power supply and ultra-high density computing racks: Custom 300kW series models are adopted.
● For small-batch commissioning of single-node or half-rack units: Adopt 120kW/130kW compact air-liquid hybrid load banks.