Hybrid Air-Liquid Cooling Simulated Load BankVILVA-GB200/GB300 1
Hybrid Air-Liquid Cooling Simulated Load BankVILVA-GB200/GB300 1

Hybrid Air-Liquid Cooling Simulated Load BankVILVA-GB200/GB300

Positioned exclusively for high-compute AI rack-scale data centers equipped with NVIDIA GB200 NVL72 and GB300 NVL72, this air-liquid hybrid simulation dummy load bank (simulated load bank) integrates liquid-cooled heating modules and air-cooled heating modules within a single rack. It replicates the power consumption layering, thermal zoning, electrical interfaces and liquid cooling pipeline parameters of real compute racks at a 1:1 ratio.
It is deployed for infrastructure acceptance of intelligent computing centers, CDU commissioning, power supply stress testing, pipeline flow distribution verification and redundancy reliability testing. Full-scenario infrastructure validation can be completed without deploying physical GPU servers on racks.
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    Positioned exclusively for high-compute AI rack-scale data centers equipped with NVIDIA GB200 NVL72 and GB300 NVL72, this air-liquid hybrid simulation dummy load bank (simulated load bank) integrates liquid-cooled heating modules and air-cooled heating modules within a single rack. It replicates the power consumption layering, thermal zoning, electrical interfaces and liquid cooling pipeline parameters of real compute racks at a 1:1 ratio.It is deployed for infrastructure acceptance of intelligent computing centers, CDU commissioning, power supply stress testing, pipeline flow distribution verification and redundancy reliability testing. Full-scenario infrastructure validation can be completed without deploying physical GPU servers on racks.
    风液冷混合负载.jpg
    Liquid Cooling Zone: Simulates high heat flux density components including Grace CPUs and Blackwell GPUs of GB200/GB300. Adopts cold plate direct cooling, and matches the inlet/outlet coolant flow rate, temperature, pressure and flow resistance parameters of DLC direct liquid cooling system.
    Air Cooling Zone: Simulates convective heat loads of auxiliary components such as memory modules, hard drives, motherboards and network adapters, and verifies hot air recirculation of precision air conditioners in the computer room as well as the rationality of hot and cold aisle layout.
    Independent Air & Liquid Cooling Control: The power of air cooling and liquid cooling can be adjusted in independent steps to reproduce actual thermal distribution under various computing load rates, and synchronously verify the coordinated heat dissipation performance of liquid cooling CDU and room precision air conditioners.
    风冷机架式负载箱.jpg

    VILVA-Fan Cooled Load Bank

    Standard 19-inch rack form factor with integrated mounting lugs for stacked rack installation.
     Equipped with redundant axial fans for forced exhaust; optional independent temperature control to start/stop fans.
     Stepwise power switching.
     Optional real-time monitoring of voltage, current, active power and internal cabinet temperature.
    Optional multi-interlock protection against overtemperature, overload, overcurrent and fan faults.
     Supports remote group control via RS485 and Ethernet Modbus TCP; multiple units can be paralleled to expand total power capacity


    Single-phase AC 220V (for IT branch circuits, C13/C14 sockets testing)


    Basic TypeRated
    Power
    Overall
    Height
    Power Adjust MethodRated CurrentMachine Size (W×H×D)Net Weight
    VILVA-AC220V-3KW-RF3kW4UPower Steps 0.5/1/1.5KW13.6A482×178×500mm22kg
    VILVA-AC220V-6kW-RF6kW6UMulti-stage power superposition27.3A482×178×500mm28kg
    VILVA-AC220V-10kW-RF10kW6UStepless adjustment range 0-10 kW45.5A482×266×520mm37kg
    VILVA-AC220V-12kW-RF12kW6U7 independent switchable power stages54.5A482×266×520mm41kg


    Three-phase AC 380/400/415V(for testing three-phase PDU incoming power and overall rack main power supply

    Suitable for supporting use with air-cooled auxiliary heat sources of GB200/GB300 cabinets.


    Basic TypeTotal Rated
    Power
    Overall WeightPower SupplySingle-phase
    Rated Current
    Adjustment Accuracy
    VILVA-AC380V-15KW-RF15KW6U3P4 Line AC380V22.8A0.1KW step-less continuous adjustment
    VILVA-AC380V-24KW-RF24kW8U3P5 Line AC400V36.5AIndependent switching per branch
    VILVA-AC380V-30kW-RF30kW8U3P5 Line AC415V43.3ARemote programmable 0-100%



    机架式液冷负载1.jpg

    VILVA-Liquid Cooled Load Bank

    Low-noise operation: Overall unit noise below 50dB, causing no noise interference during closed computer room testing.
     High power density: Delivers far higher power within the same rack unit space than air-cooled loads, suitable for segmented simulation of high-density computing racks.
     Comprehensive liquid cooling monitoring: Real-time collection of inlet/outlet coolant temperature, flow rate, differential pressure and liquid leakage signals.
     Capacity expansion via parallel connection of multiple units; supports synchronized remote cluster programmable control, ideal for batch acceptance testing of entire data centers.


    Single-phase AC 220V (for branch circuit testing of single-node servers)


    TypeRated PowerOverall WeightAdjustment MethodRated CurrentMachine Size(W×H×D)
    VILVA-AC220V-10KW-LB10kW4U0-10kW Stepless Adjustable45.5A482×178×520mm
    VILVA-AC220V-15KW-LB15KW6UMulti-stage Switching68.2A482×266×520mm


    Three-phase AC 380/400/415V (GB200/GB300)


    Total TypesTotal Rated PowerRack U HeightPower SupplySingle-phase Rated Current
    Power Step
    VILVA-AC400V-20KW-LB20kW4U3P5 Line AC400V28.9A0.1KW
    VILVA-AC415V-40KW-LB40kW6U3P5 Line AC415V57.8A0.1kW
    VILVA-AC415V-60KW-LB60kW8U3P5 Line AC415V86.7A1WHigh Precision Power Step
    VILVA-AC415V-96KW-LB96KW12U3P5 Line AC415V138.7AIndependent adjustment for each channel


    Hybrid Air-Liquid Cooling Simulated Load Bank


    GB200 TYPE

    TypeTotal Rated
    Power
    Air-cooled
    zone power
    Liquid-cooled
    zone power
    Input voltage
    standard
    Applicable objects
    VILVA-AC415V-208KW-J208kW24KW184KWAC415V/3P5GB200 NVL72 Complete Rack
    VILVA-AC400V-215KW-J216kW24KW192KWAC400V/3P5 LineGB200 High-Density Expansion Rack
    VILVA-AC380V-120KW-STD120KW15KW105KWAC380VSingle /Half Rack GB200 Node Test



    ELECTRICAL PARAMETERS

    Rated Voltage: AC380V/400V/415V+10%, Three Phase Five Lines.

    Frequency: 50Hz/60Hz Adaption.

    Power Factor: ≥0.98,THDI (Total Harmonic Distortion of Input Current) < 5%.

    Wiring Mode: Industrial 63A CEE Dual redundant connection with quick connectors and aviation plugs, equipped with 3-meter power cables.

    Adjustmen Power: 0-100% Stepless continuous adjustment with 1kW power step, remote programmable control.

    Standard Rack: 48U industrial server cabinet, 600 (W) × 1066 (D) × 2200 (H) mm.

    Mobile structure: Heavy-duty universal casters with locking brakes at the bottom.

    Designed inlet liquid temperature: 20~25°C (maximum withstand temperature: 45°C.

    Total rated flow per cabinet: 80 L/min.

    Allowable flow resistance: <1.2 bar.

     Integrated PDU: The cabinet is equipped with 8 independent branch circuit breakers inside, supporting independent switching of power per branch.

    Protection Grade: IP20 (Indoor installation in computer room.

    Triple interlock protection: Millisecond-level load cut-off triggered by low flow, overpressure and liquid leakage detection.

    Multi-point PT100 temperature measurement for the whole unit, automatic power derating upon overheating protection.

    Communication Interfaces: Local touch screen + 1000M Ethernet group control, supporting Modbus TCP and SNMP protocols.

    Data Storage: Real-time recording of power, temperature, flow and pressure curves, automatic data export, and generation of Excel-format acceptance reports.

    Noise Level: Less than 70dB at full load, much quieter than traditional air-cooled load banks.

    Design temperature difference between inlet and outlet liquid: 8–12°C.

    Interface Specification: Standard quick-disconnect liquid cooling connectors, compatible with original NVIDIA CDU pipeline interfaces.

    Monitoring items: inlet/outlet liquid temperature, instantaneous flow rate, pipeline pressure, liquid leakage detection, cold plate wall temperature, multi-point data acquisition.


    AIR-COOLING ZONE PARAMETERS

    Redundant configuration of forced axial flow fans with variable frequency speed regulation.

    Adjustable outlet air volume to simulate internal air duct resistance of servers.

    Independent temperature collection to verify the threshold of computer room return air temperature.


    GB300 TYPE

    The power consumption and heat flux density of GB300 NVL72 single cabinet are significantly increased compared with GB200. The peak power consumption of a single cabinet can reach the 250kW level. The power rating of the load is upgraded synchronously, and the partition ratio of air cooling and liquid cooling is optimized simultaneously

    TypeTotal Rated
    Power
    Fan Cooled
    Power
    Liquid Cooled
    Power
    Power SupplyApplicable Models
    VILVA-AC415V-250kW-G3250KW30kW220kWAC415V3P5 LineGB300 NVL72 Standard Complete Rack
    VILVA-AC480V-300KW-L2A300KW35KW265KWAC480V customizationGB300 Ultra High Density Expansion Rack
    VILVA-AC400V-130KW-HALF130kW16KW114KWAC400VGB300 Half Rack Node Test


    ELECTRICAL PARAMETERS

    Coolant: Deionized pure water / Special OAT antifreeze with controllable conductivity.

    Design flow rate per cabinet: >95 L/min.

    Cold plate pressure resistance: Max. 1.6 bar.

    Heat density zoning: Adjustable flow for independent branches of GPU cold plates, replicating distributed heat generation of 72 B300 GPUs.

    Temperature Rise Control: The temperature rise of the full-load complete rack is less than 15°C, fully complying with the thermal design limits of GB300 complete racks.

    Supports daisy-chain Ethernet cluster synchronous control for up to 80 load cabinets, enabling batch linkage testing of the entire computer room.

    Modular power units; failure of a single branch will not affect the load operation of other circuits of the whole unit.


    Supports parallel expansion; multiple load banks can be paralleled to simulate the total load of multi-cabinet computing clusters


    TECHNICAL ADVANTAGES

    High-fidelity operating condition replication: Independent power regulation for air-cooled and liquid-cooled zones, capable of simultaneously verifying two heat dissipation systems including liquid cooling CDU and computer room air conditioning.

    Greatly reduced test costs: No need to deploy million-level genuine GB200/GB300 computing servers for full-load aging tests. The dummy load can operate continuously 7×24h repeatedly over long term without any chip wear and tear.

    Full-dimensional quantitative acceptance: Automatically collect complete data including electric power, three-phase current and voltage, inlet/outlet liquid temperature, flow rate, pressure difference, cabinet supply and return air temperature, and directly generate acceptance documents for computer room infrastructure.

    Easy installation and deployment: Standard 48U integrated cabinet delivered as a whole unit. Testing can be initiated right after power-up and liquid cooling pipeline connection, with no on-site assembly or commissioning needed.


    Wide compatibility & customizable design: Voltages (380V/400V/415V/480V), power stages, liquid cooling connector types and communication protocols can all be customized as required, compatible with mainstream domestic and foreign CDU and liquid cooling pipeline brands.


    DELIVERY LIST

    Factory inspection report and type test certificate for complete equipment.

    Original full PDF datasheets (electrical, liquid cooling, mechanical and communication protocol manuals.

    Touch screen operation manual and remote group control host PC software.

    Supporting power cables, liquid cooling quick disconnect fittings and installation fixing accessories.

    Test data export templates and acceptance report generation tool.

    One-year warranty and on-site commissioning service specification.


    SELECTION SUGGESTIONS

    For standard GB200 NVL72 racks: Preferred model VILVA-AC415V-208kW-J.

    For infrastructure acceptance of standard GB300 complete racks: Recommended model VILVA-AC415V-250kW-G3.

    Overseas computer rooms with 480V power supply and ultra-high density computing racks: Custom 300kW series models are adopted.

    For small-batch commissioning of single-node or half-rack units: Adopt 120kW/130kW compact air-liquid hybrid load banks.



    Contact Us
    To find the best products, just work with us.
    Take a look around our website. If you have a query or you need advice, just contact us. We'll take time to help you. If you require the top-quality products, feel free to contact us.
    sales@vilva-test.com
    +86 18128682585
    Related Products
    We focus on providing load bank,EV Charger Pile Tester,PV Invert Test,UPS Aging Test,PCBA test solution,Data collection and analysis solution,AC/DC source & load solution,Aging system test for various industries
    Contact Us
    Add: 2nd Floor, Building A2, Songhu Zhigu Industrial Park, Liaobu Town, Dongguan City, Guangdong, China
    Contact person: lisa
    Tel: +86 18128682585
    E-mail:sales@vilva.net
    Customer service
    detect