loading

One-Stop Services For Various Load Bank/EV Charger Pile Tester/Auto Testing Equipment/AC or DC Source Solution

Liquid Cooling Load Bank for Efficient Thermal Management Solutions 1
Liquid Cooling Load Bank for Efficient Thermal Management Solutions 1

Liquid Cooling Load Bank for Efficient Thermal Management Solutions

It adopts water-cooled heat dissipation, which has good heat dissipation and no noise;
It can accurately measure the generator's basic functions such as steady-state three-phase voltage, current, active power, frequency, and running time;
The powerful voltage recording function can not only monitor all steady-state parameters, but also monitor sudden additions, sudden discharges, voltage, current, frequency curves, voltage, current harmonic curves and harmonic content;
It has temperature detection protection, flow protection, water level protection and water leakage protection functions;
Communication interface: Ethernet, (reserved 485 interface, following modbus-RTU; for users to develop their own software);
The software can set the power, voltage, current and other values to be loaded, and automatically calculate and load the required power level;
ON/OFF stress test can be performed;
Perform data recording and fault query in real time.
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    VILVA-AC/DC water-cooled load box, the power input adopts segmented combination control, supports sudden addition/unloading test, the resistive load adopts energy-consuming working mode, and water-cooling heat dissipation greatly ensures the reliability of constant power discharge. The water-cooled load box is mainly used to test the output power and load capacity of the ship's generator set, and to test all electrical parameters including dynamic parameters. It is used in conjunction with the host computer to achieve intelligence and automation, and complete special testing of all electrical parameters of the generator set. At the same time, charts, curves and test reports are generated to provide scientific testing methods for ship generator equipment.

    The special water-cooling load test device for ships can be equipped with special test instruments for generators to accurately measure the generator's steady-state three-phase voltage, current, active power, frequency, operating time and other basic functions; it has a powerful voltage recording function, which can not only monitor all Steady-state parameters  can also monitor sudden addition, sudden discharge, voltage, current and frequency curves, as well as voltage and current harmonic curves and harmonic content; and the voltage and frequency setting test, fluctuation test and transient test functions can be automatically tested When the load suddenly changes, the maximum and minimum values of voltage, maximum and minimum current values, maximum and minimum frequency values, and recovery time can be used in conjunction with the host computer to automatically complete the measurement of all electrical and dynamic parameters of the generator.
    b1 (12)
    6-
    7 (5)

    product details

    b5 (3)
    b5 (3)
    b4 (3)
    b4 (3)
    b3 (6)
    b3 (6)
    b2 (7)
    b2 (7)

    Product parameters

    Product model Rated power Rated voltage Loading resolution Working power supply Water discharge Box size W*D*H (mm) Weight(KG)
        VILVA-AC water-coole d load bank      
    VILVA-AC380V-200KW-RW 200 380 1 Single- phase 220Vac 30 900*1000*2000 450
    VILVA-AC380V-400KW-RW 400 380 1 60 900*1800*2000 700
    VILVA-AC380V-600KW-RW 600 380 1 90 1200*1800*2000 1000
    VILVA-AC380V-1000KW-RW 1000 380 1 120 1200*2000*2200 1500
        VILVA- DC water-cool ed load bank      
    VILVA-DC1000V-200KW-RW 200 1000 1 Single- phase 220Vac 30 900*1000*2000 450
    VILVA-DC1000V-400KW-RW 400 1000 1 60 900*1800*2000 700
    Special specifications can be customized according to customer requirements (voltage, power, step, size, display, customized model cycle is slightly longer)
    Control method: local touch screen&remote control&mobile APP
    Display parameters: voltage, current, active power, frequency, inlet and outlet water temperature, water pressure, etc.
    Load accuracy: -5%-+3%
    Display accuracy: 0.5%
    Protection level: IP20 (indoor)/IP54 (outdoor)
    Movement method: handle/caster movement/suspended ring
    Ambient temperature: -10°C~+50°C; Relative humidity: 90%; Altitude: 2500M
    Cabinet color: RAL9003
    Contact Us
    To find the best products, just work with us.
    Take a look around our website. If you have a query or you need advice, just contact us. We'll take time to help you. If you require the top-quality products, feel free to contact us.
    sales@vilva-test.com
    +86 18128682585
    Related Products
    We focus on providing load bank,EV Charger Pile Tester,PV Invert Test,UPS Aging Test,PCBA test solution,Data collection and analysis solution,AC/DC source & load solution,Aging system test for various industries
    Contact Us
    Add: 2nd Floor, Building A2, Songhu Zhigu Industrial Park, Liaobu Town, Dongguan City, Guangdong, China
    Contact person: lisa
    Tel: +86 18128682585
    Customer service
    detect