loading

One-Stop Services For Various Load Bank/EV Charger Pile Tester/Auto Testing Equipment/AC or DC Source Solution

DC Pure Resistive Load Bank for Testing and Measurement Applications 1
DC Pure Resistive Load Bank for Testing and Measurement Applications 1

DC Pure Resistive Load Bank for Testing and Measurement Applications

The fan adopts a small axial flow fan, has the characteristics of large air volume, good heat dissipation, and low noise .
With automatic over temperature protection alarm,When over heating, load bank automatic cut-off to ensure safe use .
When the load is loaded, the fan automatic starts, after unloading, the fan will automatic stop after a delay.
A new developed power consumption alloy resistor with high power density,no red heat phenomenon, long service life .
Communication interface: Ethernet (reserved 485 interface, following modbus RTU: for users to develop software themselves) .
The software of touch screen can set power value to be loaded, automatic calculate required power of load.
ON/OFF stress test, real-time data recording and fault inquiry.
5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Product Description

    VILVA-DR resistance load bank adopts segmented combination control for power input, unified segmented powerinput,supporting sudden loading/unloading, adopting an energy consuming working mode for the load,  forced air-cooled heat dissipation, greatly ensuring the reliability of constant power discharge. The The resistor are independently produced with intellectual property rights, with high power density and no red heat phenomenon.

    The automatic overheat protection function prevents overheating or burning out even the fan not rotating,keep safety and long service life. The whole machine adopts a modular design,  easy to operate and maintain. It can measure parameters such as voltage and current according to customer requirements, providing a scientific detection method for high-power DC power equipment. It meets the application fields of charging pile module testing, inverter battery discharge testing, power supply testing, battery testing, solar panel testing, electric vehicle charger testing, etc. It  is an essential detection tool for production workshops, laboratories, installation and commissioning, scientific research and development.
    b1 (11)
    6-
    7 (5)

    product details

    c1 (3)
    c1 (3)
    c2 (3)
    c2 (3)
    c3 (3)
    c3 (3)
    c4 (3)
    c4 (3)

    Product parameters

    Product model Rated power Rated voltage Resolution Air inlet and outlet direction Working power supply Box size Current range Weight
          DC Resist ive Load        
    VILVA-DC1000V-5KW-R 5 1000V 0.1 Front-back single phase 220Vac 484*600*266(6U) / 25
    VILVA-DC1000V-10KW-R 10 1000V 0.1 Bottom-top 600*750*980 / 60
    VILVA-DC1000V-20KW-R 20 1000V 0.1 Bottom-top 600*750*1115 / 85
    VILVA-DC1000V-30KW-R 30 1000V 0.1 Bottom-top 600*750*1555 / 140
    VILVA-DC1000V-40KW-R 40 1000V 0.1 Bottom-top 600*750*1555 / 160
    VILVA-DC1000V-60KW-R 60 1000V 0.1 Bottom-top 600*1000*1555 / 180
    VILVA-DC1000V-100KW-R 100 1000V 0.1 Bottom-top 600*1000*1555 / 330
    VILVA-DC1000V-150KW-R 150 1000V 0.1 Bottom-top 800*900*1750 / 480
    VILVA-DC1000V-200KW-R 200 1000V 0.1 Bottom-top 850*1000*1750 / 550
    VILVA-DC1000V-300KW-R 300 1000V 0.1 Bottom-top 380Vac 1000*1600*1600 / 1100
        DC constant working mo de Load: CC, CP, CR three working modes    
    VILVA-DC200-1000V-5KW-R 5 200~1000V 0.1 Bottom-top single phase 220Vac 600*750*980 1-25 140
    VILVA-DC200-1000V-10KW-R 10 200~1000V 0.1 Bottom-top 600*750*1115 1-50 160
    VILVA-DC200-1000V-20KW-R 20 200~1000V 0.1 Bottom-top 600*750*1335 1-100 200
    VILVA-DC200-1000V-30KW-R 30 200~1000V 0.1 Bottom-top 600*1000*1555 1-150 250
    VILVA-DC200-1000V-60KW-R 60 200~1000V 1 Bottom-top 950*1800*1640 1-300 525
    VILVA-DC200-1000V-120KW-R 120 200~1000V 1 Bottom-top 900*1000*1750 1-600 1200
    Specialspec can becustomized accordingtocustomerrequirements(customizedmodelmore longer production time)
    Control mode: local touch screen&remote control
    Noise: 65-85dB Display parameters: voltage,current, power, etc.
    Load accuracy: -5% -+2% Movement mode: handle/caster movement/lifting ring
    Display accuracy: 0.5% Protection leavel: IP20 (indoor)/IP54 (outdoor)
    Color: RAL9003 Environmental temperature: -10 ° C~+50 ° C;
    Relative humidity:  90%;  Altitude:  2500M Protection function: overvoltage, overcurrent, Overheating, fan phase sequence protection Cabinet
    Contact Us
    To find the best products, just work with us.
    Take a look around our website. If you have a query or you need advice, just contact us. We'll take time to help you. If you require the top-quality products, feel free to contact us.
    sales@vilva-test.com
    +86 18128682585
    Related Products
    We focus on providing load bank,EV Charger Pile Tester,PV Invert Test,UPS Aging Test,PCBA test solution,Data collection and analysis solution,AC/DC source & load solution,Aging system test for various industries
    Contact Us
    Add: 2nd Floor, Building A2, Songhu Zhigu Industrial Park, Liaobu Town, Dongguan City, Guangdong, China
    Contact person: lisa
    Tel: +86 18128682585
    Customer service