| Product model | VILVA-HCT photovoltaic inverter constant temperature aging room system for industrial and commercial storage | |
| Room size | Customized according to venue size | |
| Performance | temperature range | RT~60°C (±5℃) |
| temperature fluctuation | <±5℃ | |
| temperature uniformity | <±5℃ | |
| Temperature deviation | <±5℃ | |
| Heating time | Average 0.5~3°C/min | |
| Material | External material | Rock wool color steel plate |
| Internal material | Color steel plate | |
| Insulation layer internal and external materials | PU/rock wool/PU and thermal insulation wool | |
| Air duct system | Circulation fan | Axial fan/centrifugal fan |
| Heating system | Alloy resistance heating | |
| Wind channel | 3 sets of main heat dissipation ducts (one set of ducts includes an exhaust duct, which is insulated, an exhaust fan and an air supply duct, and a supply fan. The hot air is discharged to the outside and fresh air is sent from the outside to the aging room) | |
| Controlsystem | Control method | Touch screen + PLC microcomputer program control |
| Temperature control principle | Electric heating + over-temperature exhaust cooling | |
| Operation mode | Fully automatic constant temperature fixed value operation or program operation | |
| Sensor | 1 Power supply phase se uence and phase loss alarm protection 2 Fan failure (no wind) alarm protection 3 Armored sensors, each room can be equipped with 12 sets of probes to monitor the temperature status in the room | |
| Safety protection device | Motor overload alarm protection/heater overtemperature alarm protection; 4. Heater fuse open circuit alarm protection; 5. Indoor smoke sensor alarm protection, the control system is equipped with three-color indicator lights | |
| Power supply | and buzzers, all alarms are audible and visual alarms and the cause of the fault is displayed in Chinese AC380V±10%/3P/50±0.5Hz | |
| Aging house operation noise | 70 dB(A) (Tested at any point with the front of the aging room 1 meter away from the wall and 1.5m away from the ground) | |
| Heater power | 50kW | |
| Observation window | Multi-layer hollow electroplated film heated glass | |
| Other accessories | Explosion-proof lighting in the room | |