Home > Product > DC R Load Banks » DC27.5V-9.6KW-R load bank
DC27.5V-9.6KW-R load bank
Product Category:DC R Load Banks
Product Number:VILVA-1535
Product Brief:It meets the needs of full load detection of power generators, UPS power supplies, inverters, etc. It is an indispensable testing tool for production workshops, laboratories, insta...
Hotline:

 +86-18122867790

Product Details

DC27.5V-9.6KW-R load bank

DC27.5V-9.6KW-R load bank meets the needs of power supply full load detection of generator sets, UPS power supplies, inverters, etc. It is an indispensable testing tool for production workshops, laboratories, installation and commissioning, and scientific research and development.

1.The product overview

VILVA-DC27.5V-9.6KW-R load bank has built-in pure resistive load; it can simulate various power loads and meet the needs of full load detection of power generators, UPS power supplies, inverters, etc. It is the production workshop, laboratory, Installation and debugging, research and development necessary testing tools.

The host has a temperature overheating automatic alarm protection function: when there is overheating due to special reasons, the load can be automatically cut off. The load works in energy-consuming mode, and the heat dissipation uses forced air cooling. The fan adopts a small axial flow fan, which has the characteristics of large air volume, good heat dissipation and low noise.

The above characteristics make the whole machine superior to imported products in terms of safety, reliability and noise reduction.

2. Technical parameters

Equipment technical parameters

Rated voltage

27.5V

rated power

9.6KW

Power factor

R load: PF = 1.0

Load accuracy

±5%

Explicit system

nothing

Working power

Single-phase AC220V/50Hz

control method

Segmented manual adjustable

Insulation class

F

Protection level

IP20 (suitable for indoor use)

Fan noise

65 decibels

cooling method

Forced Axial Air Cooling: Side-in and back-out, back-out, with heat sinks punched on the panels around the load box for heat dissipation

Way of working

Continuous operation

Protective function

Mandatory Unloading Over-temperature Protection Over-temperature Alarm Buzzing Tips

Socket interface

Standard three-core power socket, 4 channels total 4, with fuse short circuit protection

Wiring

Each cabinet is powered by 4 outlets with 4 1.5m power lines.

External size

 6U cabinet (W 600 * Deep 482 * high 267mn); suitable for 19 inch chassis

Applicable ambient temperature

10C~+50

Mobile mode

Hand-held; fixing bracket and handle

Applicable relative humidity

95%

Altitude

2500m

Factory supplied

Appearance Fig. 1, Electrical Principle Fig. 1, Structural Schematic Fig. 1, Inspection Report 1, Instruction Qualification Certificate 1


3. The resistive load module

The resistive load module is made up of several special nickel-chromium alloy resistors. As a power consuming component, the alloy resistor is made of special alloy. The external heat sink is made of 304 stainless steel. The middle is filled with insulating medium, and the resistor is packaged in it to meet the needs of load testing. The alloy has good electrical resistance, high heat dissipation performance, uniform heat conduction, and the operating temperature is only 1/3 of the design temperature. The temperature drift is small, the resistance value is stable, and there is no red heat for a long time. It has the effects of acid and alkali resistance, salt spray resistance, rain resistance, moisture resistance and corrosion resistance, and can be used all day.

The resistive load module uses exclusive technology to fix the alloy resistance on the insulating material board. The whole module is sealed and sealed by internal insulation and insulation board to ensure insulation and safety even in wet weather. A short circuit accident caused by a drop in internal resistance due to internal resistance.

Contact Us

Shenzhen VILVA Electronic Technology Co. Ltd.

Business Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C

Factory Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C

Phone: +86-18122867790

Contact:Amy

Fax Number 086 0755 29768581

Wechat ID:shenzhenvilva

WhatsApp:+86-15814356357

Skype:live:809b341254f5b3b8

E-mail:  pm@vilva-test.com

             3525878530@qq.com

Order:DC27.5V-9.6KW-R load bank
* Indicates required
* Product Number:
* Contact: Name
* Phone:
E-mail:
* Intent to purchase:
Please fill out the procurement of products and product descriptions to facilitate our unity stocking further.

DC14V-2KW-...

DC800V-250...

DC800V-150...

DC80V/DC32...

DC75V/DC12...

Information
Home  | New Product  | Product  | Applications  | Case  | About Us  | News  | Contact Us
Copyright@ Shenzhen Vilva Electronics Co., Ltd. Copyright 2013 www.vilva.net 
tel:0086-755-27927879 fax:0755-29768581 Contact:Amy +86-18122867790  E-mail:pm@vilva-test.com
Add:2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C